16 FABRICARE circulating the coolant through the refrigeration condenser, the efficiency of the process is dependent on two factors: A. COOLANT FLOW - amount of coolant moving through the condenser. B. HEAT TRANSFER EFFICIENCY - the ability of the condenser to move heat to the coolant. Each of the above factors can be easily monitored using pressure and temperature as indicators of what is going on in the coolant system. A pressure gage and thermometer at the inlet and outlet of the coolant system located near the drycleaning machine are vital for monitoring cooling system performance. The pump must supply enough pressure and flow in sufficient quantities to push coolant through the components that require cooling on the drycleaning machine (on most machines this would include not only the refrigeration condenser but also the still condenser and solvent cooler); the pump also moves water the tower or chiller sumps, which are often located on the roof. Unfortunately, there is no hard, fast rule for nominal pressure readings. For future reference, the best method for obtaining the “numbers” is to note the drycleaning machine inlet and outlet pressure and temperature readings when the drycleaning machine is working properly. Let’s have a look at what the thermometers and pressure gages can tell us about the condition of the coolant system. Here are some scenarios for different combinations of qualitative data: 1. Inlet pressure high/outlet pressure low: A. Check for blockage inlet flow path - a clogged Y strainer between the pump and the drycleaning machine. B. Heavy scale build up - a build-up of scale inside the piping of the drycleaning machine. 2. Inlet and outlet pressure rapidly changing: A . Low coolant level in the pumping system. 3. Low inlet/high outlet pressure A. Open bypass valve on pumping system. 4. Low inlet/low outlet pressure A. Pump off. B. Clogged inlet strainer. 5. High inlet temperature/high outlet temperature: A. Water tower fan not working/chiller refrigeration system faulty. B. Pump off. 6. Slightly higher than normal inlet temperature/high outlet temperature: A. Heavy scale build up - a build-up of scale inside the piping of the drycleaning machine. B. Excessive heat source - still boil over or steam sweep valve open; steam supply valve to steam boost coil or carbon adsorber. Back to the drycleaning machine’s operation: Problems with the cooling system are most likely to appear during the dry cycle, more specifically, toward the end of the dry cycle when the drycleaning machine goes into cool down mode. During the drying mode the heat exchanger coil is transferring much of the heat from the Freon to the air stream and only a small portion of the heat load is being dumped into the refrigeration condenser. In the cool down mode solenoids and dampers change and almost the entire heat load is now dumped into the refrigeration condenser. This type of problem is indicated by the REFRIGERATION COMPRESSOR going into a high- pressure condition and tripping the REFRIGERATION HIGH PRESSURE SAFETY SWITCH. Most of the time this would cause an error message on the programmer screen and require a manual rest of the refrigeration high pressure safety switch. This condition is almost always caused by either a clogged Y strainer or excessive scaling inside the refrigeration condenser. On most drycleaning machines there is a REFRIGERATION HEAD PRESSURE ADJUSTING VALVE which controls the refrigeration head pressure by varying flow of coolant to the refrigeration condenser. This valve is adjusted to give sufficient refrigeration head pressure for efficient refrigeration system operation. When scale builds up in the refrigeration condenser past the point where the normal adjustment of the head pressure adjusting valve can compensate many drycleaners simply open the valve wider in the VERY MISTAKEN belief they have actually fixed something. What they have done is “kicked the can down the road” and will pay a lot of extra money in solvent and energy for the privilege. The accompanying illustrations show schematics for typical cooling water installations on systems using a water tower or chiller. The top illustration is what is most commonly found, the bottom is an installation WITH THE ADDITION OF VALVES 1, 2, 3 which are used when city water hook-up is included in the installation. This city water hook-up provides not only an emergency back-up for continuing operations when there is a failure in the normal cooling system as well as ready access for connecting a descaling pump. Bruce Grossman is the Chief of R&D for EZtimers Manufacturing. EZtimers is the manufacturer of the new EZ Level return tank water level control. To prevent boiler scaling and other damage the EZ Level return tank water level control replaces that troublesome ball float valve in the condensate return tank. For saving money on handling waste the SAHARA and DROP IN THE BUCKET line of high purity separator water mister/evaporators provide a thrifty, legal method to get rid of the separator water generated by your dry-cleaning machine. See our Ad in this issue and for further information on EZtimers products visit www.eztimers.com Please address any questions or comments for Bruce to bruce@eztimers.com or call (702) 376-6693. continued from page 15 FE ATURE